Refrigerant Purchases: Compliance and Cost
A practical, data-backed guide to controlling costs and automating expense workflows.
Refrigerant Purchases: Compliance and Cost For a complete overview, see our expense management guide.
As an HVAC contractor, you're likely aware of the importance of accurate refrigerant purchases to avoid penalties and ensure compliance with federal and state regulations. The Air Conditioning, Heating, and Refrigeration Certification Board (ACHR) has established rules for refrigerant purchases, including the phasedown of high-GWP refrigerants. The AIM Act's rule for leak detection, repair, recordkeeping, and the types of refrigerants being phased in or out are crucial to ensure compliance. The allowable annual leak rates for different types of refrigeration systems are 10% for comfort cooling, 20% for commercial refrigeration, and 30% for industrial process refrigeration. To avoid penalties, you must ensure that all refrigerants used are in compliance with these rules. For the bigger picture, see our guide to hvac contractor expense management software.
The rules in this guide
| Amount | Required | In Incurdesk |
|---|---|---|
| Above $75 | Itemised receipt | Checked on every expense |
| Above $250 | Written business purpose | Checked on every expense |
| Above $500 | Names of attendees | Checked on every expense |
| Above $2,500 | Senior sign-off; never auto-approved | Checked on every expense |
Each rule is checked on every expense by Incurdesk’s approval agent.
Recordkeeping and Reporting
As a small HVAC contractor, accurately recording refrigerant purchases and usage is crucial for compliance and avoiding penalties. Here's what you need to know:
To record refrigerant purchases, maintain a log or database that includes the following information:
- Date of purchase
- Type and quantity of refrigerant
- Location of the refrigerant
- Method of transportation (e.g., truck, trailer, or shipping container)
- Signature of the person who made the purchase
For leak detection and repair, ensure that you follow these steps:
- Identify the refrigerant that needs to be repaired
- Locate the refrigerant source (e.g., a leak in a system)
- Use a leak detector to confirm the presence of the refrigerant
- Repair the leak promptly to prevent further damage
- Record the repair details, including the date and time of the repair
For recordkeeping, you may need to:
- Maintain a separate log or database for refrigerant purchases and repairs
- Update your records regularly to reflect changes in your business operations
- Comfort cooling: 10%
- Commercial refrigeration: 20%
- Industrial process refrigeration: 30%
Keeping this simple: Incurdesk turns submitted expenses into clean expense reports. It is built for small hvac contractor teams. Try it free.
Phase-down of High-GWP Refrigerants
As of January 1, 2026, the manufacturing and import of new R-410A systems for residential and light commercial AC and heat pump systems will stop. However, this does not mean that current R-410A systems cannot be used. Instead, HVAC contractors and manufacturers must switch to low-GWP refrigerants such as R-454B and R-32 for new equipment.
New residential HVAC systems sold after January 1, 2025, must use refrigerants with a GWP below 750. This means that contractors must choose refrigerants with a GWP of 750 or lower to meet the new regulations.
Additionally, starting January 1, 2026, high-GWP refrigerants like R-404A, R-448A, and R-449A are banned for installation in new commercial or industrial refrigeration systems. This means that contractors must ensure that their new equipment meets the new regulations by the deadline.
In terms of recordkeeping and reporting, contractors must keep track of the type of refrigerant used in their equipment and report it to the relevant authorities.
Refrigerant Purchases Compliance and Cost
As small HVAC contractors, you need to understand the new federal and state regulations regarding refrigerant purchases and usage. The Environmental Protection Agency (EPA) has announced that it will allow the continued installation of HVAC units manufactured or imported before January 1, 2025, that use R-410A refrigerant, until existing supplies are depleted.
The EPA's final rule effective July 27, 2026, will continue to allow the installation of these units, but it's essential to note that the phase-down of high-GWP refrigerants (such as R-22 and R-410A) will eventually take effect. This means that you may need to upgrade to new refrigerants in the future.
To ensure compliance with the EPA's regulations, you should:
- Check the type of refrigerant your current HVAC units are made of. R-410A is still widely used, but some newer units may be made with R-410A or other high-GWP refrigerants.
- Verify that your existing supplies of R-410A are not depleted.
- Plan for the phase-down of high-GWP refrigerants in the future.
- Consider consulting with a qualified HVAC technician or supplier to determine the best course of action.
- Comfort cooling: 10%
- Commercial refrigeration: 20%
- Industrial process refrigeration: 30%

Leak Detection and Repair
Refrigerant Purchases Compliance and Cost
The 2026 phase-down of high-GWP refrigerants is a significant change from the previous 50-pound threshold. To ensure compliance, you must follow these rules:
- Appliances containing 15 pounds or more of an HFC refrigerant (or a substitute with a GWP greater than 53) must be subject to federal leak repair, inspection, and recordkeeping mandates by January 1, 2026.
- The allowable annual leak rates are:
- 10% for comfort cooling
- 20% for commercial refrigeration
- 30% for industrial process refrigeration
- Leaks exceeding the established thresholds must be repaired within 30 days of detection. An exception allows for 120 days if an industrial process shutdown is required.
- Service records, leak inspections, and repair documentation must be retained for at least three years.
These rules apply to all refrigerants used in your business, including R-410A, R-22, and R-410A blends. It is essential to review and comply with these regulations to avoid penalties and ensure public health and safety.
Exceptions and Exemptions
Small HVAC contractors may be exempt from certain requirements if they can demonstrate that the exemption is necessary to avoid a significant economic burden or to prevent a substantial risk of injury or loss of life. The following exceptions apply:
- Contractors who operate in areas with extremely low ambient temperatures (typically below -20°C or -4°F) may be exempt from certain requirements, such as leak detection and repair procedures.
- Contractors who use refrigerants that are not subject to the AIM Act's phasedown or do not meet the requirements outlined in the 2026 amendments may not be required to comply with certain requirements, such as leak detection and recordkeeping.
Tax rules, limits and rates change. Confirm current figures with the IRS or your accountant before you file.